fbpx

Outdoor Furnace Water Treatment

Control Chemical Treatment

Crown Royal Stoves are manufactured with 409 Titanium Enhanced Stainless Steel.
This provides you with the best corrosion resistance possible but over time calcium and magnesium can still cause scale buildup. To ensure the maximum efficiency and longevity of your Crown Royal Stove, water treatment is crucial. Treating systems with Control Chemical will prevent corrosion and scale buildup. Calcium and magnesium are commonly found in many water supplies. These impurities cause layers of scale that not only decrease heat transfer efficiency but cause pitting on the interior water jacket. Over time constant pitting will result in leaks. Once Control Chemical is added it creates the necessary barrier needed to prevent the breakdown of metals. If Control Chemical is not used right when your stove was installed, the damage may already be done.

Control Chemical and Testing Required on all Crown Royal Stoves

All Crown Royal Stoves are required to be shipped with initial recommended gallon(s) of Control chemical. Crown Royal Stoves are backed with a 20 Year Limited Warranty. To retain warranty on Crown Royal Stoves it is required to use Control chemical and submit annual samples for testing. Failure to maintain treatment at recommended levels and annual water testing will result in a voided warranty. There are many different water supplies, so not all water will be treated equally. Initial treatment of water is the same but could change over time.

treated untreated water samples

The image on the left is steel wool in untreated water after only one day. The image on the right is steel wool treated with Control Chemical. If you see your water turning a different color (and it is not from antifreeze), drain your system and retreat.

control chemical 2

Upon Installation of the Furnace:

  • Before adding treatment, fill furnace with water (NEVER fill your stove with softened water. The best water to use is distilled water. Your local dealer can test your water before filling to make sure the chlorides in your water are low enough to use in your stove.), circulate for 48 hours and check for any leaks.
  • Control Chemical is added to the water at a rate of 1 gallon for every 200 gallons of stove water.
  • After adding Control Chemical, circulate your system for 24-48 hours.
  • When collecting water samples, turn off furnace and allow water to reduce in temperature. When water is reduced to a safe temperature, collect sample.
  • Retrieve a 4 oz sample of treated water in the provided sample bottle.
  • Fill out provided label and send to required testing faculty.
  • Our testing facility analyzes the following properties of your water sample:
    • Conductivity (Electricity in water); 
    • PH (Acidity of water); 
    • Nitrite (Oxygen scavenger that is in the chemical and prevents your system from rusting); and  
    • Chloride (A naturally occurring element common in water and is a component of salt. Chloride increases the electrical conductivity of water and in turn increases its corrosivity).
  • Testing facility will send satisfactory or unsatisfactory test results back to your provided e-mail or mailing address within 4-6 weeks.
  • If your test results are unsatisfactory, you must correct and send in another sample for testing.
  • Initial dosage as follows: 
    • 3/4 of a gallon: 7200MP
    • 1 gallon: 7200E, 7300E, 7300MP, 7350MP
    • 2 gallons: 7400E, 7400MP, BIO 950
    • 3 gallons: 7500MP

CHLORIDE TESTING EXAMPLES

Unsatisfactory Test Result Example

Satisfactory Test Result Example

Skilled Testing Facility – Free Water Testing
Water samples are tested by skilled individuals that will analyze the Conductivity, PH, Nitrite, and Chloride levels. Recommendations will follow and provide actions necessary to ensure the longevity of your stove/furnace/boiler/hydronic heater. Testing results with recommendations take approximately 4-6 weeks before results are emailed or mailed. You will receive test results that are either Satisfactory or Unsatisfactory. Unsatisfactory test results will come with instructions on what to do next. 

Test results provided below for both Satisfactory and Unsatisfactory results so you know what to expect when you get your test back.

Purchasing Control Chemical
Control Chemical is specially formulated for Crown Royal Stoves. To uphold warranty no other chemical may be substituted. Consumers are encouraged to purchase the additional Control Chemical needed from a local dealership. If your dealer is unavailable please call Crown Royal Stoves directly to order.

Sample Bottles and Shipping Labels
Two sample bottles and two labels are included with every gallon of Control chemical. Replacements are free of charge and can be ordered by calling your local dealer or call us at 866-361-7355.

First Aid Procedures for Furnace Treatment Emergency Phone Number 1-800-424-9300

Water Sample Form (PDF)
Control MSDS (PDF)

Annual Water Test Reminder List

Stay updated on news about your Crown Royal Stove. Don’t miss out on your annual water test by joining this reminder list.

  • MM slash DD slash YYYY
  • This field is for validation purposes and should be left unchanged.